Set Parameters Command
Character: P or p
Decimal: 80 or 112
Hexadecimal: 050 or 080
Command Value: Unused
When a 'P' command is given all initialization parameters are updated. The minimum
requirement of this command is to set the EXTEND and RETRACT LIMITS to their
proper values (see Start-Up and Tuning). When a 'P' command is given, the motion
controller will copy the ACTUAL POSITION of the axis into the TARGET and
COMMAND POSITIONS.
Quit Events Command
Character: Q
Decimal: 81
Hexadecimal: 051
Command Value: Unused
This command stops the event control sequence. Any motion commands in progress are
not stopped. Therefore, if an axis is currently moving to 4.000”, it will continue moving
to that position; if an axis is in open loop with 1.000V drive, the drive will continue
holding that drive, etc. If you desire to stop the axis at the same time, look at the Halt
and Disable Drive Output commands.
Restore Null Drive Command
Character: R
Decimal: 82
Hexadecimal: 052
Command Value: Unused
This command restores the last saved value of null. This value will be 0 if no previous
Save Null Drive was issued.
Restore Integral Drive Command
Character: r
Decimal: 114
Hexadecimal: 072