Delta MS250 Návod k obsluze Strana 1

Procházejte online nebo si stáhněte Návod k obsluze pro Kotoučové pily Delta MS250. Delta MS250 Operator`s manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Operator's Manual

Operator's ManualMS-250 Mixed SignalOscilloscope Option

Strany 2

Operator's ManualStandard HardwareThe MS-250 is delivered with the following hardware:Part Description QTYMixed SignalAccessoryProvides 18-channe

Strany 3

MS-250 Mixed Signal Oscilloscope OptionPart Description QTY3" FlexibleGround LeadLead for grounding individual digital inputs 5GroundExtenderConn

Strany 4 - Contents

Operator's ManualAccessoriesYou may purchase these optional accessories separately to enhance the performance ofan MS-250:Accessory Part Number D

Strany 5

MS-250 Mixed Signal Oscilloscope OptionAccessory Part Number DescriptionSmall GripperProbe SetPK400-3Small gripper probe set for 0.008 inch (0.2 mm) p

Strany 6 - Precautions

Operator's ManualConnecting the Mixed Signal OptionConnecting to the OscilloscopeTo connect the Mixed Signal accessory to your oscilloscope:1. Co

Strany 7 - Specifications

MS-250 Mixed Signal Oscilloscope Option3. Connect the other end of the Bus Cable to the MS-250. Again, be sure to align thewedge and the groove. Faste

Strany 8 - Introduction

Operator's Manual5. Connect the Digital Leadset to the Digital Inputs D0 – D17 connector on the oppositeend of the MS-250 and fasten the thumb sc

Strany 9

MS-250 Mixed Signal Oscilloscope OptionDigital ConnectionsConnect the Digital Leads to the digital lines you wish to observe (using accessory micro-gr

Strany 10 - Standard Hardware

Operator's ManualDigital SetupDigital Logic SetupEach lead bank requires a Logic Setup to determine the assignment of a 1 or 0, dependingon the m

Strany 11

MS-250 Mixed Signal Oscilloscope OptionMinimum Voltage Swing (Hysteresis)You can define the minimum high voltage and maximum low voltage levels using

Strany 12 - Accessories

MS-250 Mixed SignalOscilloscope OptionOperator's ManualNovember 2014

Strany 13

Operator's ManualDigital Group SetupThis procedure organizes the digital lines into groups, which correspond to buses. Thelines within a single g

Strany 14

MS-250 Mixed Signal Oscilloscope OptionDisplaying Digital TracesThe Trace On checkbox is selected by default, so if you are connected to a live input,

Strany 15

Operator's ManualDigital bus trace 1 division high starting at position 4.Store DisplayTo store the entire group and display setup to an internal

Strany 16

MS-250 Mixed Signal Oscilloscope OptionDigital TriggeringSetting UpDigital TriggersTo access the Trigger setup dialogs, do one of the following:l Cho

Strany 17 - Digital Connections

Operator's Manual1. Open the Digital Pattern dialog.2. At the far right of the dialog, choose either Logic Bus or Logic.3. Optionally, deselect F

Strany 18 - Digital Setup

MS-250 Mixed Signal Oscilloscope OptionAnalog Pattern1. To add the analog pattern to the digital pattern, leave your digital pattern as is andskip to

Strany 19

Operator's ManualEdge TriggerEdge triggers upon a achieving a certain voltage level in the positive or negative slope ofthe waveform. It is the d

Strany 20 - Digital Group Setup

MS-250 Mixed Signal Oscilloscope OptionWidth TriggerWidth triggers upon finding a positive- or negative-going pulse width when measured at thespecifie

Strany 21 - Displaying Digital Traces

Operator's ManualGlitch TriggerGlitch triggers upon finding a fixed pulse-width time or time range.On the Trigger dialog, select Smart trigger ty

Strany 22 - Renaming Digital Lines

MS-250 Mixed Signal Oscilloscope OptionInterval TriggerInterval triggers upon finding a specific interval, the time (period) between twoconsecutive ed

Strany 23 - Digital Triggering

MS-250 Mixed Signal Oscilloscope Option Operator's Manual© 2014 Teledyne LeCroy, Inc. All rights reserved.Unauthorized duplication of Teledyne Le

Strany 24

Operator's ManualDropout TriggerDropout triggers when a signal loss is detected. The trigger is generated at the end of thetimeout period followi

Strany 25 - Analog Pattern

MS-250 Mixed Signal Oscilloscope OptionQualified TriggerQualified arms the trigger on the A event, then fires on the B event. In Normal trigger mode,i

Strany 26 - Edge Trigger

Operator's ManualMaintenanceCleaningClean only the exterior of the product using a soft cloth moistened with water or analcohol solution. Do not

Strany 27 - Width Trigger

MS-250 Mixed Signal Oscilloscope OptionThe Datasheet published on the product page contains the detailed product specifications.You can also download

Strany 28 - Glitch Trigger

Operator's ManualReferenceCertificationsEMC ComplianceEC DECLARATION OF CONFORMITY - EMCThe product meets the intent of EC Directive 2004/108/EC

Strany 29 - Interval Trigger

MS-250 Mixed Signal Oscilloscope OptionSafety ComplianceEC DECLARATION OF CONFORMITY - LOW-VOLTAGEThe product meets the intent of EC Directive 2006/95

Strany 30 - Dropout Trigger

Operator's ManualWarrantyTHE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY

Strany 31 - Qualified Trigger

MS-250 Mixed Signal Oscilloscope OptionContact UsUnited States and Canada -World Wide Corporate OfficeTeledyne LeCroy Corporation700 Chestnut Ridge Ro

Strany 32 - Maintenance

924976-00November, 2014

Strany 33

Operator's ManualContentsWelcome iiSafety 1Operating Environment 2Specifications 2Introduction 3Technical Overview 3Standard Hardware 5Accessorie

Strany 34 - Reference

MS-250 Mixed Signal Oscilloscope OptionWelcomeThank you for purchasing a Teledyne LeCroy MS-250 Mixed Signal Oscilloscope Option.The MS-250 is a power

Strany 35 - Environmental Compliance

Operator's ManualSafetyObserve these instructions to keep the product operating in a correct and safe condition.You are required to follow genera

Strany 36 - Warranty

MS-250 Mixed Signal Oscilloscope OptionOperating EnvironmentTemperature: 5 to 40 °CHumidity:Maximum relative humidity 80% (non-condensing) for tempera

Strany 37 - Contact Us

Operator's ManualIntroductionThe MS-250 Mixed Signal Oscilloscope Option is a complete system that adds digitalacquisition and triggering capabil

Strany 38 - November, 2014

MS-250 Mixed Signal Oscilloscope OptionThe minimum high voltage level may be defined by the user (using the hysteresis controls)up to 1.4 V above the

Komentáře k této Příručce

Žádné komentáře