Step 9: Connect Feedback Device
deltamotion.com 19
Verify Feedback
1. In the Axis Status Registers
pane, on the All tab, expand
the Feedback section.
For secondary inputs, expand
the Pressure/Force/Accel
Feedback section.
2. Look at the Counts register (for analog feedback, look at Volts or
Current).
It may be changing slightly.
3. Use the Direct Output command to move the axis back and forth
(as described in the Testing an Actuator section).
4. As the axis moves, look for a corresponding change in the Counts,
Volts or Current. If it does not change smoothly, recheck the
wiring, verify that the parameters on the Setup tab are correct,
and check for smoothly changing Counts, Volts or Current again.
5. Save the project and update Flash.