4. Motion Control Instructions
DVP-MC operating manual 4-61
Master scaling = 2, slave scaling = 1, master offset = 0, slave offset = 0
Master Position
Slave Position
60
180
360
360
720
When master scaling = 2, slave scaling = 1, master offset = 0, slave offset = 0, the cam curve
cycle is twice the original one and master axis takes 720°360°*2as the corresponding
current cycle.
Master scaling = 0.5, slave scaling = 1, master offset = 0, slave offset = 0
Master Positio
n
Slave Position
60
180
360
360180
When master scaling = 0.5, slave scaling = 1, master offset = 0, slave offset = 0, the cam curve
cycle is half of the original one and master axis takes180°360°/2as the corresponding
current cycle.