Delta D25886 Uživatelský manuál Strana 268

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 339
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 267
Appendix A
DVP-MC operating manual A-5
¾ Example 3: the method of revising COM2 communication format (COM2 is possessed by motion control
module.
To revise COM2 communication format, add the following program codes to CANopen Builder software.
As below figure shows, a rising edge occurs in the program and K512 (H200) is sent to D6516. Meanwhile,
COM2 communication format is revised into ASCII mode, 9600bpsBaud rate, 7Data bits, EParity,
1 (Stop bits).
Note: For Modbus communication of DVP10MC11T PLC, please refer to < DVP-ES2/EX2/SS2/SA2/SX2
operating manualProgram>.
Example on Connection of DVP10MC11T into Modbus Network:
DVP10MC11T is connected to Modbus network via RS-485 as figure below:
2
3
1
5
2
2
2
6
4
4
2
5
Device no. 1 2 3 4 5 6
Device
name
Modbus
master
Communication
cable
VFD-CM08 DVP10MC11T
AC motor
drive
Servo
drive
RS-485 Wiring:
c d e f
Master Slave Terminal resistor Shielded cable
Figure 19
D+ D- SG D+ D- SG SG D+ D-
3
4
1 2 2
3
4
Zobrazit stránku 267
1 2 ... 263 264 265 266 267 268 269 270 271 272 273 ... 338 339

Komentáře k této Příručce

Žádné komentáře