Appendix A: Command Reference
A-85
XXXX|XXXX (XX) High byte of requested data
Second scan:
Send on Command Strobe going high:
0000|XXXX|1110|0001 (0XE1) Set End Step Number
Receive after Acknowledge:
XXXX|XXXX (XX) Low byte of requested data
Send on Command Strobe going high:
0000|0000|0110|0011 (0063) End Step Number of 99
Receive after Acknowledge:
XXXX|XXXX (XX) High byte of requested data
Third scan:
Send on Command Strobe going high:
0000|XXXX|1110|0010 (0XE2) Set Parameter to Modify
Receive after Acknowledge:
XXXX|XXXX (XX) Low byte of requested data
Send on Command Strobe going high:
0000|0000|0000|0111 (0007) Select Link Value
Receive after Acknowledge:
XXXX|XXXX (XX) High byte of requested data
Fourth scan:
Send on Command Strobe going high:
0000|XXXX|1110|0011 (0XE3) Set actual value
Receive after Acknowledge:
XXXX|XXXX (XX) Low byte of requested data
Send on Command Strobe going high:
0000|0001|1101|1000 (01D8) Link Value (500)
Receive after Acknowledge:
XXXX|XXXX (XX) High byte of requested data